JIADEST / PRODUCT CATEGORY

Oil-Immersed Transformers

Oil-immersed power and distribution transformers for utility networks, substations and overhead distribution.

Oil-immersed distribution transformer with a corrugated tank and top-mounted bushings
Oil-immersed distribution transformer · corrugated-tank design

7 PRODUCT SERIES / MODELS & DATA

Choose by product duty.

Search by model or rated power ↗

Oil-immersed distribution transformers

Distribution and overhead-network transformer series.

10 kV / 20 kV Oil-Immersed Distribution Transformers reference photograph

10 kV / 20 kV Oil-Immersed Distribution Transformers

10 kV / 20 kV Oil-Immersed Distribution Transformers ↗

Series: S11 / S13 / S20 / S22

1 technical table

Sealed oil-immersed distribution transformers for 10 kV and 20 kV networks, with corrugated tanks and project-specific winding and tapping arrangements.

Voltage class
10 kV / 20 kV
Series designations
S13, S20, S22
6 published model designations

S11-M-315/10 · S11-M-2000/10 · S13-M-630/10 · S13-M-2500/10-NX3 · S20-M-2500/10-NX2 …

Preview published data
Documented model designations and ratings · first 4 rows
ModelRated capacity (kVA)Voltage class (kV)Scope / configuration note
S11-M-315/1031510Brochure / model-specific documentation; confirm selected configuration
S11-M-2000/10200010Brochure / model-specific documentation; confirm selected configuration
S13-M-630/1063010Brochure / model-specific documentation; confirm selected configuration
S13-M-2500/10-NX3250010Brochure / model-specific documentation; confirm selected configuration
10 kV / 20 kV Amorphous Alloy Oil-Immersed Transformers reference photograph

10 kV / 20 kV Amorphous Alloy Oil-Immersed Transformers

10 kV / 20 kV Amorphous Alloy Oil-Immersed Transformers ↗

Series: SH, SBH15-M-2500/10

1 technical table

Amorphous-alloy-core, oil-immersed distribution transformers for 10 kV and 20 kV networks, designed to reduce no-load losses.

Voltage class
10 kV / 20 kV
Series designations
SH, SBH15-M-2500/10
1 published model designations

SBH15-M-2500/10

Preview published data
Documented model designations and ratings · first 1 rows
ModelRated capacity (kVA)Voltage class (kV)Scope / configuration note
SBH15-M-2500/10250010Brochure / model-specific documentation; confirm selected configuration
Single-Phase Pole-Mounted Transformers reference photograph

Single-Phase Pole-Mounted Transformers

Single-Phase Pole-Mounted Transformers ↗

Series: DH15-M.R

1 technical table

DH15-M.R single-phase pole-mounted transformers for overhead distribution. The catalogue also documents a separately designated D13-M-50/10 single-phase unit.

Series designations
DH15-M.R
1 published model designations

D13-M-50/10

Preview published data
Documented model designations and ratings · first 1 rows
ModelRated capacity (kVA)Voltage class (kV)Scope / configuration note
D13-M-50/105010Separately designated single-phase unit; not a DH15-M.R model

Oil-immersed power transformers

35 kV to 220 kV power transformer series.

35 kV Oil-Immersed Power Transformers reference photograph

35 kV Oil-Immersed Power Transformers

35 kV Oil-Immersed Power Transformers ↗

1 technical table

35 kV oil-immersed power transformers for substation and industrial distribution duties. Specify voltage ratio, tapping arrangement and required load duty.

Voltage class
35 kV
1 published model designations

SZ11-2500/35

Preview published data
Documented model designations and ratings · first 1 rows
ModelRated capacity (kVA)Voltage class (kV)Scope / configuration note
SZ11-2500/35250035Brochure / model-specific documentation; confirm selected configuration

ENGINEERING SELECTION / INDUSTRY BENCHMARKS

Compare losses and impedance.

Use these published international-market examples to discuss your efficiency target and network requirements.

Liquid-immersed distribution transformer benchmarks · source table identified as EU Ecodesign Tier 2
Rated power (kVA)Voltage class scope (kV)No-load loss P0 (W)Load loss Pk (W)Short-circuit impedance uk (%)
1000Up to 2469376006
1600Up to 241080120006
2500Up to 241575185006
1000Up to 3679683606
1600Up to 361242132006
2500Up to 361811203506

The voltage-class limits above are source-table headings, not voltage ratios. P0 and Pk are different loss quantities. Compare ratings only with matching voltage class, frequency, loss evaluation conditions and test basis; request the applicable load-loss reference temperature.

Reference source & basis

Values transcribed from Eaton’s published liquid-immersed transformer technical tables ↗, checked 2 November 2026. The IEC design standard and the EU efficiency requirements are separate specifications.

JIADEST / TECHNICAL SELECTION GUIDE

Oil-immersed distribution transformer selection.

Start your specification with the reference ratings and configuration items below. Send the combination your project needs for engineering review.

Model families

S11 / S13 / S20 / S22 are industry series references. The applicable JIADEST model and design must be confirmed with the quotation.

Technical requirements to specify
ParameterReference for your inquiry
Rated power references30–2,500 kVA; nominate the capacity required for your project.
Primary voltage references6, 6.3, 10, 11, 13.8, 22 or 33 kV; specify the actual rated voltage and insulation level.
Secondary voltage references0.4, 0.415 or 0.433 kV; other requirements can be submitted for review.
Number of phasesThree-phase reference configurations.
Rated frequencySpecify 50 Hz or 60 Hz; each rating requires a corresponding design.
Vector groupDyn11 or Yyn0 reference arrangements; confirm against the system requirements.
Cooling methodONAN reference configuration; other cooling duties require a separate review.
Tap changer / tapping rangeOff-circuit reference: ±2 × 2.5%. Specify any different range or on-load requirement.
Winding materialSpecify copper or aluminum; electrical and mechanical ratings must match the selected design.
Tank / insulating liquidSpecify hermetically sealed or conservator construction, and the required insulating liquid.
Site conditionsState ambient temperature, altitude, indoor/outdoor location and corrosion conditions.
Standards for reviewIdentify the applicable IEC 60076 requirements or the project-specified standard and edition. This guide does not establish conformity.

19 REFERENCE CAPACITY RATINGS / 30–2,500 kVA

Choose a reference capacity

Each row is an illustrative starting point for an inquiry, not a confirmed stock model or a complete product datasheet. The voltage and frequency shown do not limit your project request; specify any required changes in the form.

19 reference capacities for engineering review
Rated powerPrimary / secondaryFrequencyNext step
30 kVA10 / 0.4 kV50 HzRequest review ↗
50 kVA10 / 0.4 kV50 HzRequest review ↗
63 kVA10 / 0.4 kV50 HzRequest review ↗
80 kVA10 / 0.4 kV50 HzRequest review ↗
100 kVA10 / 0.4 kV50 HzRequest review ↗
125 kVA10 / 0.4 kV50 HzRequest review ↗
160 kVA10 / 0.4 kV50 HzRequest review ↗
200 kVA10 / 0.4 kV50 HzRequest review ↗
250 kVA10 / 0.4 kV50 HzRequest review ↗
315 kVA10 / 0.4 kV50 HzRequest review ↗
400 kVA10 / 0.4 kV50 HzRequest review ↗
500 kVA11 / 0.415 kV50 HzRequest review ↗
630 kVA10 / 0.4 kV50 HzRequest review ↗
800 kVA10 / 0.4 kV50 HzRequest review ↗
1,000 kVA11 / 0.415 kV50 HzRequest review ↗
1,250 kVA10 / 0.4 kV50 HzRequest review ↗
1,600 kVA11 / 0.415 kV50 HzRequest review ↗
2,000 kVA10 / 0.4 kV50 HzRequest review ↗
2,500 kVA10 / 0.4 kV50 HzRequest review ↗

Performance and drawing data

Request these design-specific values with your quotation. They cannot be determined from the series name or rated capacity alone.

No-load / load losses
To be stated in the approved technical schedule, with reference temperature and tolerances.
Short-circuit impedance
To be agreed for the voltage ratio, rated power and system fault requirements.
Insulation and sound levels
To be confirmed against the selected design and applicable test requirements.
Dimensions / total mass
To be provided on the approved outline drawing; enclosure and accessories affect the result.
Oil mass / volume
Applicable to oil-immersed units only; mass in kg and volume in litres must be specified separately.
Test reports / conformity documents
Request documents identifying the actual manufacturer, model, scope and applicable standard.
About these reference configurations

Prepared from public industry product information, with conflicting or design-specific performance values excluded. Industry examples do not verify JIADEST ratings or certifications.

PROJECT SPECIFICATION

Prepare your inquiry.

Send the required ratings, application and available drawings. Refer to the published model tables for the documented design.

  1. 01Rated power and supply configuration
  2. 02Input and output voltage, frequency and phase
  3. 03Load duty, cooling and installation conditions
  4. 04Required dimensions, tests and documentation
  5. 05Quantity, destination and required delivery date

TALK TO JIADEST

Discuss your oil-immersed transformers requirements.

Share your rated capacity, voltages, application and destination. Our team can review the configuration and documentation required for your order.

Request a quotation ↗
JIADEST / LET’S TALK POWER

Planning a power project?

Share your requirements when you’re ready. Our team can help with equipment selection.

Need to share more? Use the detailed inquiry form ↗