Transformer manufacturing. Global supply.
Qingdao, China
◎ English⌄
EnglishSpanishComing soonPortugueseComing soonFrenchComing soonRussianComing soonItalianComing soonGermanComing soonDutchComing soonArabicComing soonKoreanComing soonJapaneseComing soonHindiComing soonThaiComing soonTurkishComing soonVietnameseComing soonIndonesianComing soon

JIADEST / PRODUCT CATEGORY

Dry-Type Transformers

Cast-resin, amorphous-core and station-service dry-type transformers for building and industrial power distribution.

Three-phase cast-resin dry-type transformer with exposed coil assemblies, terminal connections and cooling fans
Cast-resin dry-type transformer · coil assembly and cooling arrangement

6 PRODUCT SERIES / MODELS & DATA

Choose by product duty.

Search by model or rated power ↗

Cast-resin distribution transformers

Medium-voltage power distribution for buildings and industrial installations. Compare voltage class and the published capacity basis.

10 kV Cast-Resin Dry-Type Transformers reference photograph

Cast-Resin Dry-Type Transformers

10 kV Cast-Resin Dry-Type Transformers ↗

Series: SCB10 / SCB11 / SCB12 / SCB13 / SCB14 / SCB18

1 technical table

10 kV cast-resin dry-type transformers for indoor distribution, commercial buildings, transport facilities and industrial loads. SCB10, SCB11, SCB12, SCB13, SCB14 and SCB18 designations are documented in the brochure and report listings.

Voltage class
10 kV
Published capacity range
30–2500 kVA
Series designations
SCB12, SCB14, SCB18
7 published model designations

SCB10-400/10 · SCB10-2000/10 · SCB11-2500/10 · SCB12-2500/10 · SCB13-2500/10-NX3 …

Preview published data
Documented model designations and ratings · first 4 rows
ModelRated capacity (kVA)Voltage class (kV)Scope / configuration note
SCB10-400/1040010Brochure / model-specific documentation; confirm selected configuration
SCB10-2000/10200010Brochure / model-specific documentation; confirm selected configuration
SCB11-2500/10250010Brochure / model-specific documentation; confirm selected configuration
SCB12-2500/10250010Brochure / model-specific documentation; confirm selected configuration

Amorphous-core dry-type transformers

Distribution transformer series with an amorphous alloy core. Review the series documentation for the required design.

Station-service dry-type transformers

Auxiliary power for substations and station facilities. These have a different duty and capacity range from main distribution transformers.

Cast-resin construction reference

Brochure information about resin insulation and cooling. This overview does not provide a rated model schedule.

JIADEST / TECHNICAL SELECTION GUIDE

Cast-resin dry-type transformer selection.

Start your specification with the reference ratings and configuration items below. Send the combination your project needs for engineering review.

Model families

SCB10, SCB11, SCB12, SCB13, SCB14 and SCB18 designations appear in the supplied transformer brochure and model-specific records. The SCB10 registration ranges cover 30–630 kVA and 630–2,500 kVA; confirm the selected model and configuration before ordering.

Technical requirements to specify
ParameterReference for your inquiry
Rated power references30–2,500 kVA; nominate the capacity required for your project.
Primary voltage references6, 6.3, 10, 11, 13.8, 22 or 33 kV; confirm the voltage class and insulation design separately.
Secondary voltage references0.4, 0.415 or 0.433 kV; nominate the required secondary voltage.
Number of phasesThree-phase reference configurations.
Rated frequencySpecify 50 Hz or 60 Hz; each rating requires a corresponding design.
Vector groupDyn11 or Yyn0 reference arrangements; confirm against the system requirements.
Cooling methodAN reference configuration. AF operation and any revised rating need a separate design confirmation.
Tap arrangementOff-circuit reference: ±2 × 2.5%; confirm the arrangement and adjustment requirements.
Winding materialSpecify copper or aluminum; the final design determines performance and dimensions.
Thermal class / temperature riseState the required thermal class and winding temperature-rise limits; confirmation is design-specific.
Enclosure / temperature monitoringSpecify enclosure IP rating, ventilation clearances, temperature sensors and controller requirements.
Standards for reviewIdentify the applicable IEC 60076-11 requirements or project-specified standard and edition. This guide does not establish conformity.

18 REFERENCE CAPACITY RATINGS / 30–2,500 kVA

Choose a reference capacity

Each row is an illustrative starting point for an inquiry, not a confirmed stock model or a complete product datasheet. The voltage and frequency shown do not limit your project request; specify any required changes in the form.

18 reference capacities for engineering review
Rated powerPrimary / secondaryFrequencyNext step
30 kVA10 / 0.4 kV50 HzRequest review ↗
50 kVA10 / 0.4 kV50 HzRequest review ↗
80 kVA10 / 0.4 kV50 HzRequest review ↗
100 kVA10 / 0.4 kV50 HzRequest review ↗
125 kVA10 / 0.4 kV50 HzRequest review ↗
160 kVA10 / 0.4 kV50 HzRequest review ↗
200 kVA10 / 0.4 kV50 HzRequest review ↗
250 kVA10 / 0.4 kV50 HzRequest review ↗
315 kVA10 / 0.4 kV50 HzRequest review ↗
400 kVA10 / 0.4 kV50 HzRequest review ↗
500 kVA11 / 0.415 kV50 HzRequest review ↗
630 kVA10 / 0.4 kV50 HzRequest review ↗
800 kVA10 / 0.4 kV50 HzRequest review ↗
1,000 kVA11 / 0.415 kV50 HzRequest review ↗
1,250 kVA10 / 0.4 kV50 HzRequest review ↗
1,600 kVA11 / 0.415 kV50 HzRequest review ↗
2,000 kVA10 / 0.4 kV50 HzRequest review ↗
2,500 kVA10 / 0.4 kV50 HzRequest review ↗

Performance and drawing data

Request these design-specific values with your quotation. They cannot be determined from the series name or rated capacity alone.

No-load / load losses
To be stated in the approved technical schedule, with reference temperature and tolerances.
Short-circuit impedance
To be agreed for the voltage ratio, rated power and system fault requirements.
Insulation and sound levels
To be confirmed against the selected design and applicable test requirements.
Dimensions / total mass
To be provided on the approved outline drawing; enclosure and accessories affect the result.
Test reports / conformity documents
Request documents identifying the actual manufacturer, model, scope and applicable standard.
About these reference configurations

Prepared from public industry product information, with conflicting or design-specific performance values excluded. Industry examples do not verify JIADEST ratings or certifications.

PROJECT SPECIFICATION

Prepare your inquiry.

Send the required ratings, application and available drawings. Refer to the published model tables for the documented design.

  1. 01Rated power and supply configuration
  2. 02Input and output voltage, frequency and phase
  3. 03Load duty, cooling and installation conditions
  4. 04Required dimensions, tests and documentation
  5. 05Quantity, destination and required delivery date

TALK TO JIADEST

Discuss your dry-type transformers requirements.

Share your rated capacity, voltages, application and destination. Our team can review the configuration and documentation required for your order.

Request a quotation ↗
JIADEST / LET’S TALK POWER

Planning a power project?

Share your requirements when you’re ready. Our team can help with equipment selection.

Need to share more? Use the detailed inquiry form ↗