Transformer manufacturing. Global supply.
Qingdao, China
◎ English⌄
EnglishSpanishComing soonPortugueseComing soonFrenchComing soonRussianComing soonItalianComing soonGermanComing soonDutchComing soonArabicComing soonKoreanComing soonJapaneseComing soonHindiComing soonThaiComing soonTurkishComing soonVietnameseComing soonIndonesianComing soon

JIADEST / Isolation Transformers

Neutral-to-Earth Voltage Reduction Isolation Transformers

Manufacturer’s series: DM

Electrically separated primary and secondary windings for equipment isolation and noise control.

Search the complete technical catalog ↗
Neutral-to-Earth Voltage Reduction Isolation Transformers product photograph
Open reference photograph ↗
Product reference photograph. Refer to the technical tables and drawings for each configuration.

Overview

An isolation transformer provides electrical separation between input and output windings. The brochure describes early adoption in European power applications and use in electronics, industrial and mining enterprises, machine tools and mechanical equipment to reduce or eliminate neutral-to-earth voltage. It may also supply general control circuits, safety lighting and indicator lamps.

Functions described in the brochure

The primary and secondary circuits are electrically insulated. High-frequency core losses help suppress high-frequency interference entering control circuits.

The brochure discusses floating secondary systems only for limited supply areas with short circuits and low earth-capacitance current. It also describes earthing one secondary terminal, designated as neutral, to reduce neutral-to-earth voltage below 0.2 V. These are descriptions of the source text, not a substitute for the project earthing and protection design.

The brochure emphasises separation from hazardous voltage as a personnel-protection function.

Principle and application examples

Operation is based on electromagnetic induction. The brochure describes a commonly used 1:1 transformer for servicing equipment with an unearthed secondary, but also explains that isolation transformers need not have a 1:1 ratio.

Examples include valve amplifiers, valve radios, oscilloscopes, lathe control supplies, colour-television servicing and air-conditioning equipment.

Electrostatic shielding

A non-closed copper sheet or non-magnetic conductive paper screen is installed between primary and secondary windings and connected to the enclosure. A surrounding shielding enclosure and screened winding terminals may be added to reduce external electromagnetic interference.

The brochure states that this leaves predominantly magnetic coupling and can reduce equivalent distributed capacitance below 0.01 pF, thereby reducing capacitive current and suppressing interference from the supply and other circuits.

Ratings and dimensions

Ratings and dimensions
CapacityInput voltageFrequencyOutput voltageOverall dimensions (mm)
0.5KVA220V or 380V50–60Hz220V or 380V280×140×155
1KVA220V or 380V50–60Hz220V or 380V285×155×162
1.5KVA220V or 380V50–60Hz220V or 380V320×195×190
2KVA220V or 380V50–60Hz220V or 380V440×300×320
3KVA220V or 380V50–60Hz220V or 380V440×300×320
5KVA220V or 380V50–60Hz220V or 380V440×300×320
6KVA220V or 380V50–60Hz220V or 380V440×300×320
8KVA220V or 380V50–60Hz220V or 380V440×300×320
10KVA220V or 380V50–60Hz220V or 380V300×320×420

DIMENSIONS / CONNECTIONS / SOURCE DATA

Technical information and original product sheets.

The original sheet retains all dimensioned drawings, connection diagrams, table footnotes and published values. It is supplied in its original language for direct verification against the English specification.

Open original sheet at native resolution ↗
View complete original technical sheet (Chinese)Original technical sheet with complete specifications and dimension drawings for Neutral-to-Earth Voltage Reduction Isolation Transformers

TALK TO JIADEST

Discuss your Isolation Transformers requirements.

Use the exact model, voltage, current or power rating, duty cycle and drawing reference when requesting a quotation. Confirm source discrepancies and project-specific requirements in the approved technical agreement.

Request a quotation ↗
JIADEST / LET’S TALK POWER

Planning a power project?

Share your requirements when you’re ready. Our team can help with equipment selection.